CODESYS Applications

This menu item is used to configure the settings for the behavior of the CODESYS applications. This menu entry is only available for devices with CODESYS.


Figure: CODESYS Applications

Table:  Applications Settings

Setting

Description

Default

Exception Hardware GlobalStop

Each hardware exception will result in a stop of all applications.

Off

Bootproject RetainMissmatch Exception

If the check of the retain variables failed, the boot application is stopped and an exception is triggered.

Off

Bootproject RetainMissmatch Init

If the check of the retain variables failed, the retain variables are reinitialized.

On

RetainType

Retain Storage Location:

InSRAM: External SRAM module.

OnPowerfail: Saved in a File, located in the PlcLogic directory (manualy or on shutdown)

InSRAM

Table:  TargetVisu Settings

Setting

Description

Default

TargetVisu HideCursorCompletely

Hide mouse cursor always in the targetvisu

Off

Table:  System Settings

Setting

Description

Default

Scheduler Interval Us

CODESYS Scheduler Interval used for Software Watchdog Handling.

1000

Channel Timeout

CODESYS IDE communication timeout in us.

300000

Maximum processor load of all PLC tasks

Maximum plc load, used in plcload check task.

95

OPCUA Enable

Enbale/Disable OPCUA Feature

On

The settings can be saved with the Apply button or discarded with the Reload button.
When changing the settings, a restart of the device is necessary.